Ultrasonic heat meter CF Echo II Qn 2,5
NUR für Direktmessung, Rücklauf, 260 mm, DN 25, G5/4B, PN 25, inkl. Konformitätsentgelt 2021 - 2026
  • Item number: 611471000065
310,80 €

Excluding 19% VAT., plus shipping

Not available now!

Shipping time: 9 - 11 workdays


Description
short information
Description
Ultrasonic heat meter Allmess CF Echo II HA includes removable microprocessor electronic unit with attached flow sensor and temperature sensors without fitting.

display: LC with 3 levels
? level 1: energy, volume, test, optional extern water meter
? level 2: maximum values for flow rate, performance, flow temperature, temperature difference, operating failures, optional extern water meter data, M-Bus adress and baud rate
? level 3: 13 cutoff date values for energy and volume, optional water meter, software version
real-time clock
advance warning for rising soiling
connection cable: 1,5 m, optional 5 m
battery: 3,6 V lithium

electronic unit
temperature range: 0-180°C
temperature difference: 3-160 K
temperature measuring cycle: 4s
data memory: EEPROM
display: 7 digits
unit: MWh, optional GJ, KWh
interface: ZVEI (M-BUS protocoll)
environment temperature: max. +55°C
protection class: IP 64
environment class: C
installation: on flow sensor or wall

flow sensor
ultrasonic flow meter with direct measurement of the speed of sound 
metrological class: 2 according EN 1434
measuring range: Qs+10%/Qstart > 1000:1
volume measuring cycle: 3s
temperature range: 130°C, temporary 150°C
compressive strength: PN 25
pressure loss: < 0,15 bar
protection class: IP66 & 67
integrated measruing point for temperature

   